Question and answerEXC-QA-240

Why do newer markings say 'Ex db' or 'Ex eb' instead of 'Ex d' or 'Ex e'?

excodex editorial teamCertification and testing

Abstract

The added letter is the level of protection (a, b or c), which matches the EPL Ga, Gb or Gc. IEC 60079-1:2014 split flameproof into da, db, dc and IEC 60079-7:2015 split increased safety into eb and ec. Older Ex d and Ex e equal today's db and eb.

The extra lower-case letter is the level of protection: a, b or c, matching the equipment protection level (EPL) Ga, Gb or Gc. Flameproof and increased safety used to have only one level, so Ex d and Ex e needed no letter. When IEC 60079-1:2014 introduced the flameproof levels da, db and dc, and IEC 60079-7:2015 the increased safety levels eb and ec, the marking had to say which level applies. An older Ex d or Ex e product corresponds to today's db or eb (EPL Gb).

Short answer

  • db = flameproof enclosure, level b, EPL Gb. eb = increased safety, level b, EPL Gb.
  • The level letter lets one protection standard cover several EPLs: ec (Gc) is the former Zone 2 type nA moved into the increased safety standard, and dc (Gc) took over enclosed-break devices from the type n standard.
  • IEC 60079-7:2015 states that the former marking e is replaced by eb and nA by ec: a product certified to the new edition takes the new marking even if nothing else about it changes.
  • Equipment already marked Ex d or Ex e is not downgraded or invalidated by the new marking; it is selected as Gb equipment.
  • Intrinsic safety has used levels (ia, ib) for decades; encapsulation, pressurisation and dust enclosures followed in the 2000s.

How the level letters arrived, concept by concept

Type of protectionOlder markingCurrent levels (EPL)Where the change came from
Flameproof enclosuredda (Ga), db (Gb), dc (Gc)IEC 60079-1:2014 (edition 7); da only for catalytic sensors of portable gas detectors, dc from type n enclosed-break devices
Increased safetye (and nA for Zone 2)eb (Gb), ec (Gc)IEC 60079-7:2015 (edition 5), which absorbed type nA
Intrinsic safetyia, ibia (Ga), ib (Gb), ic (Gc)ic added in EN 60079-11:2007
Encapsulationm, then ma, mbma (Ga), mb (Gb), mc (Gc)ma and mb in EN 60079-18:2004, mc added in EN 60079-18:2009
Pressurisationp, then px, py, pzpxb, pyb (Gb), pzc (Gc)px, py, pz from the mid-2000s; EPL letter added in IEC 60079-2:2014
Dust enclosuretDta (Da), tb (Db), tc (Dc)EN 60079-31:2009

The IEC 60079-0 marking list of 2004 still shows plain "d" and "e" next to "ia", "ib", "ma", "mb", "px", "py" and "pz". The EPL concept followed in IEC 60079-0 of 2007 (EN 60079-0:2009 in Europe), and over the next decade each protection standard was revised so that its level letters line up with the EPL.

Why the change was made

One standard, several levels. Before the change, Zone 2 versions of increased safety and flameproof devices lived in a separate standard (type of protection "n", IEC 60079-15) with their own codes nA and nC. Moving them into the main standards as ec and dc put each technique and its relaxed Zone 2 variant under one set of rules.

A self-checking marking. With the level letter, the type of protection and the EPL at the end of the marking agree: Ex db IIC T4 Gb, Ex ec IIC T4 Gc, Ex ia IIC T6 Ga. An inspector can see at a glance whether a combination is consistent.

Clear selection. The letter makes it obvious that eb and ec are not interchangeable even though both are "increased safety". Without it, an e marking could not show whether the product was built to the full Zone 1 requirements.

What it means for existing and mixed installations

The US Coast Guard's hazardous location guidance notes that the EPL-related letter did not exist in earlier editions of the standards and may be missing from older markings. That is expected and is not a defect. Treat older markings as follows:

Marking on existing equipmentRead asZones
Ex d IIB T4 or EEx d IIB T4Flameproof, level equivalent to db, EPL Gb1 and 2
Ex e II T3 or EEx e II T3Increased safety, level equivalent to eb, EPL Gb1 and 2
Ex nA II T3Non-sparking, equivalent to ec, EPL Gc2 only
Ex ia IIC T4Intrinsic safety ia, EPL Ga0, 1 and 2

Both the European notified bodies' list of changes between standard editions and the foreword of IEC 60079-7:2015 note that such revisions should not normally affect equipment already placed on the market. Inspection of older equipment is done against the standards that applied when it was installed (IEC 60079-17). A replacement bought today will simply carry the new marking.

Common mistakes

  • Rejecting a spare because it says Ex db while the drawing says Ex d. For selection they are the same level; check group, T-class and ambient range instead.
  • Reading the b in db as gas group IIB. It is the level of protection; the gas group appears separately.
  • Assuming ec is a lighter eb that still suits Zone 1. It is the former nA, Zone 2 only.

Related on excodex

Standards and further reading

  • IEC 60079-1:2014, flameproof enclosures "d", with levels da, db and dc (a 2026 edition has since been published): preview
  • IEC 60079-7:2015, increased safety "e", levels eb and ec; foreword on the marking changes from e to eb and nA to ec: law.resource.org
  • IEC 60079-0:2004, marking list before EPLs: law.resource.org
  • ExNB clarification sheet ExNB/10/388/CS, changes between European standard editions: prestations.ineris.fr (PDF)
  • US Coast Guard OCS National Center of Expertise, Drill Down 26, protection techniques: dco.uscg.mil

This article is general technical information prepared by the excodex editorial team. It does not replace the applicable standards, the equipment certificates and instructions, national regulations or the assessment of a competent person.