Question and answerEXC-QA-249

What does IP66 on an Ex label have to do with explosion protection?

excodex editorial teamCertification and testing

Abstract

IP66 means dust-tight and protected against powerful water jets (IEC 60529). It is not explosion protection and says nothing about gas. But several protection concepts depend on a minimum IP rating, for example Ex e (IP54 with bare live parts) and Ex t (IP5X or IP6X).

On its own, nothing: IP66 is an ingress protection rating under IEC 60529. The first 6 means dust-tight, the second 6 means protected against powerful water jets. It does not make equipment explosion-protected and it says nothing about gas. It still matters, because several types of protection only work if the enclosure keeps out dust and water, and their standards set a minimum IP rating.

Short answer

  • IP66 = dust-tight (6) + powerful water jets (6) in the IP code of IEC 60529. IP tests use dust and water, never gas.
  • An IP66 enclosure is not suitable for a hazardous area unless it also carries an Ex marking for the zone. See the related question on IP65 in Zone 21.
  • Some concepts rely on IP. Increased safety (Ex e) needs at least IP54 for enclosures with bare live parts; dust protection by enclosure (Ex t) needs IP5X or IP6X by dust group and level; pressurisation (Ex p) mostly IP4X.
  • For other concepts IP is for the environment. A flameproof (Ex d) enclosure contains an explosion through its flamepaths; its IP rating protects the contents from weather and washdown.
  • Where Ex safety depends on IP, IEC 60079-0 has the IP test done after the impact test (and, for non-metallic enclosures, after the thermal endurance tests), so the rating is proven on a stressed enclosure.

Reading the two digits

DigitValueMeaning (IEC 60529)
First (solids, dust)5Dust-protected: some dust may enter, not enough to interfere with operation or safety
First6Dust-tight: no ingress of dust
Second (water)4Splashing water from any direction
Second5Water jets
Second6Powerful water jets
Second7Temporary immersion

An X in place of a digit, as in IP6X, means that characteristic is not specified. The dust-related Ex requirements are therefore often written as IP5X or IP6X.

Where the IP rating is part of the explosion protection

Type of protectionMinimum degree of protectionWhy
Ex e, eb and ec (IEC 60079-7)IP54 with bare live parts; IP44 with insulated live parts only (lower values only with an X certificate and a clean location)Dust and moisture would erode creepage and clearance distances, the core of the concept
Ex t, dust (IEC 60079-31, as summarised by NSW TestSafe)IIIC: IP6X for ta, tb and tc. IIIB: IP6X for ta and tb, IP5X for tc. IIIA: IP6X for ta, IP5X for tb and tcThe enclosure itself is the protection: dust must not reach ignition sources inside
Ex p (IEC 60079-2:2014)IP4X for pxb, pyb and pzc with indicator; IP3X for pzc with alarmThe enclosure must hold the overpressure and keep out objects
Ex i (IEC 60079-11)Often IP20, or IP54 where reduced separations rely on pollution degree 2; the certificate states what appliesSeparation distances are protected from dust and moisture
Ex d (IEC 60079-1)No IP rating for the flameproof principle itselfFlamepaths cool escaping gases; gaskets for IP must follow the standard's rules

IEC 60079-7 notes explicitly that the degree of protection requirements of general industrial standards are not applied directly to Ex equipment. The 2024 edition of IEC 60079-14 adds an informative annex listing the minimum IP code for each type of protection, which installers can use as a cross-check.

Practical case: choosing between two junction boxes

A buyer compares two boxes for a Zone 1 offshore deck that is washed down with hoses. Box A is an industrial box rated IP66 with no Ex marking. Box B is marked Ex eb IIC T6 Gb and IP66. Only box B can go into Zone 1: its IP rating is part of an Ex certificate, and the increased safety concept depends on it. Box A is weather-proof but not explosion-protected. For Box B, the IP rating holds only while every cable gland and blanking plug also maintains it, which is why Ex e certificates often name the required IP rating of entry devices as a condition.

Common mistakes

  • "IP66 means explosion-proof." It means dust and water resistance. Gas can enter any IP-rated enclosure through seals and breathing.
  • Using an IP6X enclosure without an Ex t marking in Zone 21 or 22. Ex t also limits surface temperature and is tested to Ex rules.
  • Losing the IP rating at installation: unsealed glands, missing O-rings, unused entries left open, damaged lid gaskets.
  • Adding silicone or gaskets to Ex d flamepaths to improve IP. Only what the certificate and standard allow may be used.

Related on excodex

Standards and further reading

  • IEC 60529, degrees of protection provided by enclosures (IP code), public copy of the 2013 consolidated edition: law.resource.org (PDF)
  • IEC 60079-7, increased safety "e", degrees of protection (public copy of 2015): law.resource.org (PDF)
  • IEC 60079-11, intrinsic safety "i", enclosures (public copy of 2011; edition 7, 2023, is current): law.resource.org (PDF)
  • IEC 60079-2:2014, pressurised enclosures "p", design criteria table: law.resource.org (PDF)
  • IEC 60079-0, test sequence for enclosures (public copy of 2004): law.resource.org (PDF)
  • IEC 60079-31:2022, dust ignition protection by enclosure "t"; NSW TestSafe summary of its IP requirements: nsw.gov.au
  • IEC 60079-14:2024, informative annex on minimum IP code by type of protection (contents in the preview): standards.iteh.ai (PDF)

This article is general technical information prepared by the excodex editorial team. It does not replace the applicable standards, the equipment certificates and instructions, national regulations or the assessment of a competent person.